Comparative study on code-based linear evaluation of an existing RC building damaged during 1998 Adana-Ceyhan Earthquake


Toprak A. E., Gulay F. G., Ruge P.

Conference on Seismic Engineering Conference, Calabar, Nijerya, 8 - 11 Temmuz 2008, cilt.1020, ss.753-754 identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Cilt numarası: 1020
  • Basıldığı Şehir: Calabar
  • Basıldığı Ülke: Nijerya
  • Sayfa Sayıları: ss.753-754
  • İstanbul Teknik Üniversitesi Adresli: Evet

Özet

Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana- Ceyhan Earthquake in Turkey, the seismic action of Ms =6.3 with a maximum ground acceleration of 0.28g It is a six- storey RC residential building with a total of 14.65 in height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40m x 7.80m = 127.90 m(2) with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.