Investigation of non-sinusoidal rotor bar current phenomenon in induction machines - Influence of slip and electric loading


Gundogdu T., Zhu Z., Mipo J., Farah P.

22nd International Conference on Electrical Machines, ICEM 2016, Lausanne, İsviçre, 4 - 07 Eylül 2016, ss.419-425 identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Doi Numarası: 10.1109/icelmach.2016.7732560
  • Basıldığı Şehir: Lausanne
  • Basıldığı Ülke: İsviçre
  • Sayfa Sayıları: ss.419-425
  • Anahtar Kelimeler: Induction motors, rotor bar current, saturation, slip
  • İstanbul Teknik Üniversitesi Adresli: Hayır

Özet

© 2016 IEEE.Rotor bar current of an induction machine (IM) designed by using the same stator outer diameter, stack length, air-gap length, output power and rated speed as the Toyota Prius 2010 interior permanent magnet machine is investigated. It is observed that in some cases the rotor bar current waveform can be non-sinusoidal even if the stator windings are fed with a sinusoidal source. The conditions for such non-sinusoidal rotor bar current to occur and the reasons behind this phenomenon are investigated by finite element method, with particular reference to the influence of slip and electric loading.