ESTIMATION OF ADULT PATIENT DOSES FOR CHEST X-RAY EXAMINATIONS AND COMPARISON WITH DIAGNOSTIC REFERENCE LEVELS (DRLS)


Mor H. B. , Altinsoy N., Soyler I.

RADIATION PROTECTION DOSIMETRY, cilt.182, sa.3, ss.377-385, 2018 (SCI İndekslerine Giren Dergi) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 182 Konu: 3
  • Basım Tarihi: 2018
  • Doi Numarası: 10.1093/rpd/ncy076
  • Dergi Adı: RADIATION PROTECTION DOSIMETRY
  • Sayfa Sayıları: ss.377-385

Özet

The aim of this study was to evaluate the radiation doses to patient during chest (posterior anterior/and lateral) examinations. The study was performed in three public hospitals of I. stanbul province with a total of 300 adult patients. Entrance surface dose (ESD) measurements were conducted on computed radiography, digital radiography and screen film system. ESD was estimated by using International Atomic Energy Agency (IAEA) model and Davies model which are the common indirect models. Results were compared with diagnostic reference levels from the European Commission, IAEA and National Radiological Protection Board. Although the results are compatible with the international diagnostic reference levels, they present variations between the hospitals. Dose variations for the same type of X-ray examination support the idea that further optimization is possible.