ANALYSIS OF VIBRATION SIGNALS RELATED TO FUEL TANK IN A PASSENGER COACH


Seker S., Taskin S., Akinci T. C.

IEEE 16th Signal Processing and Communications Applications Conference, Aydın, Türkiye, 20 - 22 Nisan 2008, ss.42-43 identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Basıldığı Şehir: Aydın
  • Basıldığı Ülke: Türkiye
  • Sayfa Sayıları: ss.42-43
  • İstanbul Teknik Üniversitesi Adresli: Evet

Özet

In this study, the data which was taken from accelerometer located in vertical direction to fuel tank chassis of a traveler bus has been analyzed. Firstly vibration signal related to the endurance of the connection has been observed as a raw data on the time-frequency plane and then it has been passed from a critical frequency 20 Hz low pass filter and power spectrum changes have been observed. After this, critical frequency value whose peak value is about 11 Hz has been forced mechanically to the construction which consists of fuel tank has been determined. In addition, it was determined that 11 Hz emerged at about 240 second on the time scale and it has been observed that big amplitude has also been created by this frequency on the time serial.